Single-Phase Isolation Transformer for Medical and Control Equipment

Quantity:
SKU: 3065766957
Model: FPIT

{{ variable.name }}

{{ value.name }}
Single-Phase Isolation Transformer for Medical and Control Equipment
FPIT single-phase isolation transformer, 1 kVA to 5,000 kVA, CRGO core, copper or aluminum windings, electrostatic shield option, IP21 or IP23 enclosure.
single-phase-isolation-transformer
Single-Phase Isolation Transformer for Medical and Control Equipment
single-phase isolation transformer, FPIT isolation transformer, medical isolation transformer, control equipment isolation transformer

Single-Phase Isolation Transformer for Medical and Control Equipment

Model FPIT · Single Phase · 120 V – 690 V secondary · Class F / Class H

FPIT single-phase isolation transformer for medical and control loads

Product Summary

The FPIT single-phase isolation transformer delivers reliable galvanic isolation between primary and secondary circuits for single-phase loads such as medical equipment, control equipment and sensitive electronic systems. A low-loss CRGO core and high-conductivity copper or aluminum windings support rated capacities from 1 kVA to 5,000 kVA, primary voltage up to 15 kV and secondary voltage from 120 V to 690 V. An optional electrostatic shield helps reduce common-mode noise reaching sensitive downstream devices.

Key Features

  • Galvanic Isolation for Sensitive LoadsSeparates primary and secondary circuits to support medical, control and electronic equipment power systems.
  • Optional Electrostatic ShieldA copper or aluminum shielding layer between windings reduces common-mode noise and electrical interference.
  • Low-Loss CRGO CoreGrain-oriented electrical steel with optimized magnetic circuit design lowers no-load losses and audible noise.
  • Class F / Class H InsulationHigh-performance epoxy resin, Nomex, polyester and high-temperature insulating paper, with 80 K or 115 K temperature rise options.
  • Compact Enclosure OptionsAN or AF cooling with indoor or outdoor powder-coated steel enclosure rated IP00, IP21 or IP23.
  • Market ComplianceBuilt to applicable IEC, IEEE, ANSI and UL requirements, with CE certification under EN IEC 61558-1, EN IEC 61000-6-1 and EN IEC 61000-6-3.

Technical Specifications

PhaseSingle Phase (three-phase units also available in the FPIT range)
Rated Capacity1 kVA – 5,000 kVA
Primary VoltageUp to 15 kV / Customized
Secondary Voltage120 V – 690 V / Customized
Frequency50 / 60 Hz
Cooling MethodAN / AF
Insulation ClassClass F / Class H
Temperature Rise80 K / 115 K / Customized
ConnectionDelta / Wye / Zig-Zag / Customized
Vector GroupCustomized according to application
Tap Range±2 × 2.5% / Customized
EnclosureIndoor / Outdoor
Protection DegreeIP00 / IP21 / IP23 / Customized
InstallationFloor-Mounted
Applicable StandardsIEC / IEEE / ANSI / UL, according to market requirements

Models and Options

The FPIT range includes general-purpose, drive isolation, K-factor, single-phase and three-phase isolation transformers. Single-phase units are ordered by rated capacity, primary and secondary voltage, tap range, winding material, electrostatic shield requirement, cooling method and enclosure type, with impedance, connection and vector group set to the application.

Materials and Structure

The magnetic circuit uses high-quality grain-oriented electrical steel with an optimized core design. Copper or aluminum conductors are wound with a reinforced insulation system that may include epoxy resin, Nomex, polyester insulation and high-temperature insulating paper. Where electrical noise must be limited, a copper or aluminum electrostatic shield is placed between the primary and secondary windings. The heavy-duty powder-coated steel enclosure protects the unit in demanding environments.

Applications

  • Healthcare: hospitals, operating rooms, medical equipment power
  • Control and automation equipment
  • Commercial buildings: offices, hotels, shopping centers
  • Renewable energy: inverter and auxiliary power circuits
  • Data center UPS and PDU auxiliary circuits
  • Infrastructure and transportation auxiliary systems

Customization

Primary and secondary voltages, rated capacity, impedance, tap configuration, temperature rise, winding material, electrostatic shielding, cooling method and enclosure protection degree are configured per application. Production follows the applicable IEC, IEEE, ANSI and UL requirements for the destination market.

FAQ

Where is a single-phase isolation transformer typically used?

It is commonly applied to medical equipment power systems, control and automation equipment, and other sensitive electronic loads that require galvanic isolation.

What secondary voltages are available?

Secondary voltage ranges from 120 V to 690 V and can be customized, with primary voltage available up to 15 kV.

Is an electrostatic shield necessary?

It is optional. A copper or aluminum shielding layer between the primary and secondary windings helps reduce common-mode noise and electrical interference.

What insulation class and temperature rise can be specified?

Class F or Class H insulation is available, with temperature rise of 80 K, 115 K or a customized value.

Which cooling and enclosure options are offered?

AN or AF cooling with indoor or outdoor enclosure, protection degree IP00, IP21 or IP23, floor-mounted installation.

Which standards and certifications apply?

Units are designed and manufactured to applicable IEC, IEEE, ANSI and UL requirements; the isolation transformer carries CE certification under EN IEC 61558-1:2019, EN IEC 61000-6-1:2019 and EN IEC 61000-6-3:2021.

Inquiry Information

Contact: Yu Cao

Email: info@js-firstpower.com

Tel: +86 130 7404 8223 · WhatsApp: +86 150-0369-3908

Web: www.firstpowerglobal.com

To receive a configuration, please provide the load type, rated capacity, primary and secondary voltage, tap range, electrostatic shield requirement and the enclosure protection degree needed.

Image Filename and Alt Suggestions

isolation-transformer-fpit-single-phase-front-view.png — Alt: FPIT single-phase isolation transformer front view

isolation-transformer-fpit-single-phase-enclosure.png — Alt: FPIT single-phase isolation transformer powder-coated steel enclosure

Images shown are of the FPIT isolation transformer series. Final dimensions and enclosure depend on the selected rating and protection degree.