{{ variable.name }}
Model FPIT · Single Phase · 120 V – 690 V secondary · Class F / Class H

The FPIT single-phase isolation transformer delivers reliable galvanic isolation between primary and secondary circuits for single-phase loads such as medical equipment, control equipment and sensitive electronic systems. A low-loss CRGO core and high-conductivity copper or aluminum windings support rated capacities from 1 kVA to 5,000 kVA, primary voltage up to 15 kV and secondary voltage from 120 V to 690 V. An optional electrostatic shield helps reduce common-mode noise reaching sensitive downstream devices.
| Phase | Single Phase (three-phase units also available in the FPIT range) |
|---|---|
| Rated Capacity | 1 kVA – 5,000 kVA |
| Primary Voltage | Up to 15 kV / Customized |
| Secondary Voltage | 120 V – 690 V / Customized |
| Frequency | 50 / 60 Hz |
| Cooling Method | AN / AF |
| Insulation Class | Class F / Class H |
| Temperature Rise | 80 K / 115 K / Customized |
| Connection | Delta / Wye / Zig-Zag / Customized |
| Vector Group | Customized according to application |
| Tap Range | ±2 × 2.5% / Customized |
| Enclosure | Indoor / Outdoor |
| Protection Degree | IP00 / IP21 / IP23 / Customized |
| Installation | Floor-Mounted |
| Applicable Standards | IEC / IEEE / ANSI / UL, according to market requirements |
The FPIT range includes general-purpose, drive isolation, K-factor, single-phase and three-phase isolation transformers. Single-phase units are ordered by rated capacity, primary and secondary voltage, tap range, winding material, electrostatic shield requirement, cooling method and enclosure type, with impedance, connection and vector group set to the application.
The magnetic circuit uses high-quality grain-oriented electrical steel with an optimized core design. Copper or aluminum conductors are wound with a reinforced insulation system that may include epoxy resin, Nomex, polyester insulation and high-temperature insulating paper. Where electrical noise must be limited, a copper or aluminum electrostatic shield is placed between the primary and secondary windings. The heavy-duty powder-coated steel enclosure protects the unit in demanding environments.
Primary and secondary voltages, rated capacity, impedance, tap configuration, temperature rise, winding material, electrostatic shielding, cooling method and enclosure protection degree are configured per application. Production follows the applicable IEC, IEEE, ANSI and UL requirements for the destination market.
Where is a single-phase isolation transformer typically used?
It is commonly applied to medical equipment power systems, control and automation equipment, and other sensitive electronic loads that require galvanic isolation.
What secondary voltages are available?
Secondary voltage ranges from 120 V to 690 V and can be customized, with primary voltage available up to 15 kV.
Is an electrostatic shield necessary?
It is optional. A copper or aluminum shielding layer between the primary and secondary windings helps reduce common-mode noise and electrical interference.
What insulation class and temperature rise can be specified?
Class F or Class H insulation is available, with temperature rise of 80 K, 115 K or a customized value.
Which cooling and enclosure options are offered?
AN or AF cooling with indoor or outdoor enclosure, protection degree IP00, IP21 or IP23, floor-mounted installation.
Which standards and certifications apply?
Units are designed and manufactured to applicable IEC, IEEE, ANSI and UL requirements; the isolation transformer carries CE certification under EN IEC 61558-1:2019, EN IEC 61000-6-1:2019 and EN IEC 61000-6-3:2021.
Contact: Yu Cao
Email: info@js-firstpower.com
Tel: +86 130 7404 8223 · WhatsApp: +86 150-0369-3908
Web: www.firstpowerglobal.com
To receive a configuration, please provide the load type, rated capacity, primary and secondary voltage, tap range, electrostatic shield requirement and the enclosure protection degree needed.
isolation-transformer-fpit-single-phase-front-view.png — Alt: FPIT single-phase isolation transformer front view
isolation-transformer-fpit-single-phase-enclosure.png — Alt: FPIT single-phase isolation transformer powder-coated steel enclosure
Images shown are of the FPIT isolation transformer series. Final dimensions and enclosure depend on the selected rating and protection degree.